A wide range of calorimeters are available to meet different needs of the user. Up to four independent calorimeters can be used simultaneously with TAM IV, to perform repetitive or different types of experiments. TAM IV is totally modular and enables a smaller system to be added to increase sample capacity or functionality. With the addition of a multicalorimeter, holding six independent minicalorimeters, the sample throughput is increased. While the standard version may be sufficient for many applications, the 48 channel version of TAM IV, which enables as many as 48 simultaneous measurements, is recommended for high sample throughput.
- Micro XL
- Microcalorimeter
- Minicalorimeter
- Multicalorimeter
- Macrocalorimeter
- Nanocalorimeter
- Precision Solution Calorimetry
- Isothermal Titration Calorimetry
- Vacuum/Pressure Calorimeter
The
Micro XL is the most sensitive large volume
calorimeter for the TAM IV with unique
capability to test batteries of various sizes
and shapes. The Micro XL is a twin type
calorimeter with a user accessible reference
vessel for optimal thermal balance and the most
accurate enthalpy measurements. Experiments can
be conducted under passive storage conditions,
or in conjunction with an external battery
cycler to evaluate battery charging and
discharging dynamics.
Microcalorimeter
The
20 ml Microcalorimeter is a heat flow
calorimeter of twin type. It has been designed
to hold large samples, (e.g. batteries) and for
experiments requiring a large gas phase above
the sample. The microcalorimeter can be used
with all 20 ml static ampoules and the 20 ml
micro reaction system including titration
facilities and control of the relative humidity
during measurement.
The 20ml Microcalorimeter is also the only calorimeter that can be used with the micro solution ampoule. This ampoule is designed for dissolution of very small amounts of solids (a few mg) in different solvents and is ideal for dissolution of slowly soluble substances. The heat of dissolution and the kinetics of dissolution can be studied.
Minicalorimeter
The
Minicalorimeter is a 4 ml Microcalorimeter with
a special design to reduce the space occupied by
the calorimeter inside the thermostat. The
reference is positioned below the sample ampoule
which allows up to 48 Minicalorimeters to be
positioned in the thermostat. The
Minicalorimeter is used in the Multicalorimeter
and in the TAM 48 thermostat. It has been
designed for increased sample throughput and is
recommended for compatibility and stability
testing.
Multicalorimeter
The
TAM Multicalorimeter contains six
Minicalorimeters. It is intended for use with
the TAM IV thermostat to increase the sample
throughput. The TAM IV thermostat can hold up to
24 individual calorimeters, as well as other
types of calorimeters such as a Nanocalorimeter
or a Precision Solution Calorimeter. These
combinations offer the highest flexibility by
combining high sensitivity with high sample
throughput. It can be used for all applications
designed for individual Minicalorimeters.
Macrocalorimeter
The Macrocalorimeter
is a large volume calorimeter designed for
accurate heat flow measurements of samples
requiring volumes up to 125 mL. The
Macrocalorimeter is of minicalorimeter design
with sample above reference, but with a
user-changeable reference for optimal
performance. The Macrocalorimeter is suitable
for battery testing but also for large and
heterogeneous sample within food technology and
ecological sciences.
Nanocalorimeter
The
Nanocalorimeter is the most sensitive
calorimeter for the TAM IV, and is typically
used in the isothermal mode. It combines high
sensitivity with excellent baseline stability
which makes it ideal for isothermal titration
calorimetry (ITC) in studying molecular
interactions. The nanocalorimeter holds all
closed ampoules up to 4 ml. For highest
sensitivity it is used with the 1 ml titration
ampoule and a similar ampoule as reference. This
reference ampoule contains an inert substance,
(e.g. water or sand) in order to balance the
heat capacity of the two sides. Thus, under
normal conditions the heat flow associated with
the reference ampoule will be negligible.
Precision Solution Calorimetry
Solution
Calorimetry refers to the determination of the
heat of dissolution when a solid is dissolved in
a liquid, or two liquids are mixed. The TAM
Precision Solution Calorimeter is a single
position, semi-adiabatic calorimeter for high
precision measurements of the heat generated or
consumed when a solid or liquid sample is
dissolved or diluted into a solvent. The
instrument is designed for highest accuracy and
precision and is used in general thermodynamic
investigations as well as for quantitative
analytical measurements of various solid state
phases. It is available with a 25 ml or 100 ml
vessel, and is intended for use with the TAM IV
thermostat up to 80 °C.
Precision Titration Calorimeter
The Precision Titration Calorimeter is a single position, semi-adiabatic calorimeter intended for use with the TAM IV Thermostat. It provides high precision measurements of the heat generated or consumed when a solid or liquid sample is dissolved or diluted into a solvent. Utilizing the same configuration as the Precision Solution Calorimeter but with additional functionality, it is possible to inject small quantities of a solute into the stirred solution in order to investigate binding or complexation phenomena. Repeated injections can be performed by use of a syringe pump.
The Precision Titration Calorimeter is designed for highest accuracy and precision and is used in general thermodynamic investigations as well as for quantitative analytical measurements of various solid state phases.
Isothermal Titration Calorimetry
Isothermal
Titration Calorimetry requires the highest level
of calorimetric sensitivity and stability,
efficient titrant delivery, and a user-friendly
platform which facilitates easy cleanup and
rapid turnaround. Employing unique and
proprietary technology, the TAM IV is the ideal
system for Isothermal Titration Calorimetry and
excels in the most demanding ITC applications
such as ligand binding.
The TAM Isothermal Titration Calorimetry (TAM-ITC) system consists of a nanocalorimeter, 1 ml removable titration ampoule with stirring facilities, and a precision syringe pump for efficient titrant delivery. The TA Instruments nanocalorimeter is the most sensitive calorimeter available for the TAM IV, and can readily detect microjoule level heat flow. In power compensation mode, the response time of the calorimeter is optimized, and the temperature of the sample is held virtually isothermal. This is a major benefit over competitive designs, in which the sample temperature is allowed to drift during titration.
Vacuum/Pressure
Calorimeter
These stainless steel ampoules are designed to hold vacuum or pressure up to 10 bar. The pressure in the ampoule can be monitored at the same time heat flow is measured. This is ideal for the study of samples generating gaseous products during a reaction. The ampoule is available in 4 and 20 ml sizes.